NR 445.09(4)(a)1.a.
a. Company name, contact name, phone number and address of the owner or operator of the engine.
NR 445.09(4)(a)1.j.
j. The manufacturer's performance warranty for the control device expressed as a particulate matter emission rate in grams per brake horsepower-hour.
NR 445.09(4)(a)1.k.
k. The test method used by the manufacturer to determine the particulate matter emission rate in the manufacturer's performance warranty for the control device.
NR 445.09(4)(a)2.
2. Except as provided for in
subd. 3., an owner or operator complying with the 85% control requirement in
sub. (3) (a) 1. shall achieve compliance and submit in writing to the department no later than June 30, 2007, the information in
subd. 1. a. to
i. and the results of an emission test conducted to demonstrate compliance with the requirement. A copy of the test results shall also be maintained at the location where the engine is operated.
NR 445.09(4)(a)3.
3. Subdivisions 1. or
2. notwithstanding, an owner or operator of an engine manufactured or last rebuilt prior to July 1, 2004, may, in lieu of meeting the applicable control requirement in
sub. (3) (a) 1. or
2., operate the engine until January 1, 2011 without a particulate matter control device, provided they do all of the following:
NR 445.09(4)(a)3.a.
a. Submit in writing to the department no later than June 30, 2007, a statement relaying their intent to cease operating the engine before January 1, 2011 and the information in
subd. 1. a. to
f.
NR 445.09(4)(a)3.c.
c. Submit in writing to the department no later than January 31, 2011 a confirmation that the engine ceased operating on or before December 31, 2010.
NR 445.09(4)(b)
(b) An owner or operator complying with an emission rate requirement in
sub. (3) (a) 3. or
4. shall achieve compliance and submit all of the information in
par. (a) 1. a. to
L. in writing to the department no later than 10 calendar days after startup. A copy of the information shall also be maintained at the location where the engine is operated.
NR 445.09(4)(c)
(c) An owner or operator complying with the best available control technology requirement in
sub. (3) (a) 3. or
4., or a facility constructed or last modified after July 1, 2004, subject to
sub. (3) (c), shall submit information describing how the best available control technology requirement will be met in a permit application in accordance with
s. NR 406.03. Compliance with the best available control technology requirement shall be achieved and demonstrated in accordance with the permit.
NR 445.09 Note
Note: Section
NR 406.03 requires that owners or operators receive a construction permit prior to commencing operation of the source.
NR 445.09(4)(d)
(d) The owner or operator of a facility constructed or last modified before July 1, 2004, subject to
sub. (3) (c) shall do both of the following:
NR 445.09(4)(d)2.
2. Submit information describing how the best available control technology requirement will be met on the application forms required for an operation permit, an amendment to an application, renewal of the operation permit, or for a significant revision under
s. NR 407.13, as applicable.
NR 445.09(4)(e)
(e) Any submission made under this subsection shall be signed by the responsible official designated by the owner or operator of source for this purpose, with a dated statement that the information submitted is accurate to the best of the responsible official's knowledge and belief and that all of the requirements of this section have been met.
NR 445.09 Note
Note: The address for submission of information under pars. (a) and (b) is:
Wisconsin Department of Natural Resources
Bureau of Air Management
PO Box 7921
Madison WI 53707-7921
Attention: Compression Ignition Engine Notification.
Application forms for pars. (c) and (d) may be obtained from, and submitted to:
Wisconsin Department of Natural Resources
Bureau of Air Management
PO Box 7921
Madison WI 53707-7921
Attention: Construction Permit (or) Attention: Operation Permit (as appropriate).
NR 445.09(5)(a)(a) An owner or operator choosing to comply with the 85% control requirement of
sub. (3) (a) 1. shall, for each engine, comply with the requirements of
ss. NR 439.06 and
439.07. The particulate matter emission reduction across a control device shall be determined by the following equation:
% reduction = 100 x (baseline emissions – controlled emissions)/(baseline emissions)
NR 445.09(5)(b)
(b) Testing under
par. (a) shall be conducted prior to the submission deadline in
sub. (4) (a) 2. Subsequent testing and notification shall be conducted whenever the particulate matter emission control device used to achieve the 85% emission reduction is replaced. The department shall be notified of the results of subsequent tests in writing no later than 60 calendar days after the completion of the test.
NR 445.09(6)
(6) Recordkeeping. In addition to meeting the recordkeeping requirements of
s. NR 439.04 (1) and
(2), an owner or operator shall:
NR 445.09(6)(a)
(a) Keep records of maintenance performed on any particulate matter emission control device used to comply with
sub. (3).
NR 445.09(6)(b)
(b) For any engine that stays or that is intended to stay in a single location for any 12 consecutive month period, keep the following records:
NR 445.09(6)(b)1.
1. The amount of fuel oil combusted on a monthly basis for any engine not using a certified control device.
NR 445.09(6)(b)2.
2. The power rating and days of operation of any CI engine used to substitute power under
sub. (1) (d).
NR 445.09 History
History: CR 02-097: cr.
Register June 2004 No. 582, eff. 7-1-04;
CR 07-076: am. (1) (e) 1. (intro.) and 2. (intro.)
Register July 2008 No. 631, eff. 8-1-08;
CR 15-005: am. (1) (c), (2), cr. (3) (d)
Register November 2015 No. 719, eff. 12-1-15.
NR 445.10
NR 445.10 Control and compliance requirements for the handling and storage of coal. NR 445.10(1)
(1)
Applicability. This section applies to the owner or operator of any stationary source that handles or stores 1,000 tons or more of coal in any 12 consecutive month period.
NR 445.10(2)
(2) Requirements for outdoor fugitive coal dust emissions. No later than June 30, 2007, the owner or operator of a source that handles coal or maintains a coal storage pile shall achieve compliance with this section by doing all of the following:
NR 445.10(2)(a)
(a) Having the ability to control, in a timely manner, outdoor fugitive coal dust emissions in an effort to prevent emissions off the source property.
NR 445.10 Note
Note: Examples of measures that would meet the ability to control requirement include active measures such as the application of water or chemical dust suppressants, passive measures such as the use of enclosed delivery or handling systems or solid fencing, or access to third-parties to provide dust suppression, as appropriate. The intent of this section is to allow facilities that suppress dust using water to manage the amount of water applied to avoid potential boiler, handling, or other operational problems, as long as there is sufficient dust control so as not to cause excessive outdoor fugitive coal dust emissions.
NR 445.10(2)(b)
(b) Developing and implementing a plan to control outdoor fugitive coal dust emissions in an effort to prevent emissions off the source property. The plan shall include all of the following:
NR 445.10(2)(b)1.
1. Identification of all sources of outdoor fugitive coal dust emissions from coal handling and coal storage piles on the source property.
NR 445.10(2)(b)2.
2. A description of the measures that can be taken to control, in a timely manner, outdoor fugitive coal dust emissions from all sources identified under
subd. 1. under the following conditions:
NR 445.10(2)(b)2.d.
d. When equipment used to control outdoor fugitive coal dust emissions malfunctions.
NR 445.10 Note
Note: Suppliers of coal may want to consult with users in development of the plan to ensure that use of the controls provided for in par. (a) does not result in operational problems at a source combusting coal.
Examples of periods of high activity include periods when the daily handling of coal is much greater than usual, such as when unloading a large number of coal shipments at the close of the shipping season. Examples of periods of increased probability of fugitive coal dust emissions include periods or a combination of periods of drought, freezing weather, or forecasts of high winds exceeding 25 miles per hour.
NR 445.10(2)(d)
(d) Keeping a copy of the plan and records of all actions taken at the facility for inspection upon request.
NR 445.10(3)
(3) Requirements for non-fugitive coal dust emissions to the ambient air. No later than June 30, 2007, the owner or operator subject to this section shall, for any non-fugitive source of coal dust emissions exhausted through a fabric filter to the ambient air, do one of the following:
NR 445.10(3)(a)
(a) Limit visible emissions from each source to 10% opacity.
NR 445.10(3)(b)
(b) Limit the quantity, concentration or duration of potential to emit emissions of respirable coal dust from all sources so that ambient air concentration off the source property is less than 21.6
µg/m
3 for any 24 hour averaging period. The owner or operator may rely on information generated by either the EPA screening
or refined dispersion model to demonstrate meeting the concentration in this paragraph.
NR 445.10(4)
(4) Compliance certification. No later than June 30, 2007, the owner or operator of a source subject to this section shall certify the source's compliance status. An owner or operator of a source that has requirements at least as stringent as the requirements in
sub. (2) or
(3) in a permit or order may so state in his or her certification.
NR 445.10 Note
Note: This is a one-time certification. Certification forms may be obtained from, and submitted to:
Wisconsin Department of Natural Resources
Bureau of Air Management
PO Box 7921
Madison WI 53707-7921
Attention: NR 445 Certification form for handling and storage of coal.
NR 445.10 History
History: CR 02-097: cr.
Register June 2004 No. 582, eff. 7-1-04.
NR 445.11
NR 445.11 Compliance requirements for sources of incidental emissions. NR 445.11(1)
(1) The owner or operator of a facility described by a standard industrial classification code listed in Table D, as described in the Standard Industrial Classification Manual, 1987, incorporated by reference in
s. NR 484.05 (1), or that has actual annual emissions of less than 5 tons of particulate matter and less than 3 tons of volatile organic compounds, shall meet the requirements of
subs. (2) to
(4) if any of the following apply:
NR 445.11(1)(a)
(a) The facility includes operation of one or more of the following processes:
NR 445.11(1)(a)1.
1. A compression ignition internal combustion engine with rated brake power greater than 100 horsepower used as a power source.
NR 445.11(1)(a)6.
6. Manufacture or treatment of a pesticide, rodenticide, insecticide, herbicide or a fungicide resulting in an emission of a hazardous air contaminant listed in Table B of
s. NR 445.07.
NR 445.11(1)(a)7.
7. Manufacture or treatment of a pharmaceutical resulting in an emission of a hazardous air contaminant listed in Table C of
s. NR 445.07.
NR 445.11(1)(b)
(b) The presence of one or more of the substances in Table E at the facility is indicated by one of the following:
NR 445.11(1)(b)1.
1. The substance is listed on an approved material safety data sheet or is otherwise brought into the facility.
NR 445.11(1)(b)2.
2. The substance is reasonably expected to be created at the facility through a combustion process or manufacturing process, or through the treatment of raw materials or waste.
NR 445.11 Note
Note: The department will develop a list of the hazardous air contaminants it has determined to be potentially emitted from the processes listed in sub. (1) (a) 2. to 5. This list may be obtained by calling the Environmental Analysis and Outreach Section of the Bureau of Air Management at 608-266-7718.
NR 445.11(3)
(3) The owner or operator of a facility meeting the criteria in
sub. (1) (b) shall meet the applicable requirements in
s. NR 445.07 (1) for any hazardous air contaminants listed in Table A of
s. NR 445.07.
NR 445.11(4)
(4) The owner or operator subject to
sub. (2) or
(3) shall do both of the following:
NR 445.11 Note
Note:
Owners and operators of sources affected by this section should refer to chs. NR 406, 407 and 438 to determine whether there are applicable requirements in those chapters for hazardous air contaminants identified under this section.
- See PDF for table